Follow
Jakub Parak
Jakub Parak
Firstbeat Technologies Oy
Verified email at firstbeat.com
Title
Cited by
Cited by
Year
Evaluation of wearable consumer heart rate monitors based on photopletysmography
J Parak, I Korhonen
2014 36th annual international conference of the IEEE engineering in …, 2014
1822014
Evaluation of the beat-to-beat detection accuracy of PulseOn wearable optical heart rate monitor
J Parak, A Tarniceriu, P Renevey, M Bertschi, R Delgado-Gonzalo, ...
2015 37th Annual International Conference of the IEEE Engineering in …, 2015
1282015
Accuracy of Firstbeat Bodyguard 2 beat-to-beat heart rate monitor
J Parak, I Korhonen
White Pap Firstbeat Technol Ltd, 2013
962013
ECG signal processing and heart rate frequency detection methods
J Parák, J Havlík
Proceedings of Technical Computing Prague 8, 2011, 2011
742011
Evaluation of accuracy and reliability of PulseOn optical heart rate monitoring device
R Delgado-Gonzalo, J Parak, A Tarniceriu, P Renevey, M Bertschi, ...
2015 37th Annual International Conference of the IEEE Engineering in …, 2015
702015
Application of optical heart rate monitoring
M Lemay, M Bertschi, J Sola, P Renevey, J Parak, I Korhonen
Wearable sensors, 105-129, 2014
702014
Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation
J Harju, A Tarniceriu, J Parak, A Vehkaoja, A Yli-Hankala, I Korhonen
Physiological measurement 39 (6), 065007, 2018
612018
Estimating heart rate, energy expenditure, and physical performance with a wrist photoplethysmographic device during running
J Parak, M Uuskoski, J Machek, I Korhonen
JMIR mHealth and uHealth 5 (7), e7437, 2017
422017
The accuracy of atrial fibrillation detection from wrist photoplethysmography. a study on post-operative patients
A Tarniceriu, J Harju, ZR Yousefi, A Vehkaoja, J Parak, A Yli-Hankala, ...
2018 40th Annual International Conference of the IEEE Engineering in …, 2018
292018
Detection of beat-to-beat intervals from wrist photoplethysmography in patients with sinus rhythm and atrial fibrillation after surgery
A Tarniceriu, J Harju, A Vehkaoja, J Parak, R Delgado-Gonzalo, ...
2018 IEEE EMBS International Conference on Biomedical & Health Informatics …, 2018
222018
Comparison of heart rate monitoring accuracy between chest strap and vest during physical training and implications on training decisions
J Parak, M Salonen, T Myllymäki, I Korhonen
Sensors 21 (24), 8411, 2021
192021
Ectopic beat detection from wrist optical signals for sinus rhythm and atrial fibrillation subjects
S Haddad, J Harju, A Tarniceriu, T Halkola, J Parak, I Korhonen, ...
Mediterranean Conference on Medical and Biological Engineering and Computing …, 2019
122019
Towards 24/7 continuous heart rate monitoring
A Tarniceriu, J Parak, P Renevey, M Nurmi, M Bertschi, ...
2016 38th Annual International Conference of the IEEE Engineering in …, 2016
122016
System analyze of the Windkessel models
J Hauser, J Parak, M Lozek, J Havlik
space 100, 5, 2012
102012
W2e-–wellness warehouse engine for semantic interoperability of consumer health data
H Honko, V Andalibi, T Aaltonen, J Parak, M Saaranen, J Viik, I Korhonen
IEEE Journal of Biomedical and Health Informatics 20 (6), 1632-1639, 2015
92015
Heart rate detection from ballistocardiogram
J Parak
Proceedings of International Student Conference on Electrical Engineering 1, 1-5, 2012
92012
Performance of wrist photoplethysmography in monitoring atrial fibrillation in post cardiac surgery patients
A Tarniceriu, V Vuohelainen, S Haddad, T Halkola, J Parak, J Laurikka, ...
2019 Computing in Cardiology (CinC), Page 1-Page 4, 2019
82019
Device for long term measurement of heart rate
J Parak, J Dvorak, J Havlik
Proceedings of the 4th International Symposium on Applied Sciences in …, 2011
82011
Accuracy of Firstbeat BodyGuard 2 beat-to-beat heart rate monitor. 2015
J Parak, I Korhonen
72017
A Modular System for Rapid Development of Telemedical Devices.
J Havlik, L Lhotska, J Parak, J Dvorak, Z Horcik, M Pokorny
J. Univers. Comput. Sci. 19 (9), 1242-1256, 2013
72013
The system can't perform the operation now. Try again later.
Articles 1–20