Prediction of 3D Cardiovascular hemodynamics before and after coronary artery bypass surgery via deep learning G Li, H Wang, M Zhang, S Tupin, A Qiao, Y Liu, M Ohta, H Anzai Communications biology 4 (1), 99, 2021 | 70 | 2021 |
Haemodynamic effects of stent diameter and compaction ratio on flow-diversion treatment of intracranial aneurysms: a numerical study of a successful and an unsuccessful case M Zhang, Y Li, X Zhao, DI Verrelli, W Chong, M Ohta, Y Qian Journal of biomechanics 58, 179-186, 2017 | 39 | 2017 |
Numerical simulation of aneurysmal haemodynamics with calibrated porous-medium models of flow-diverting stents Y Li, M Zhang, DI Verrelli, W Chong, M Ohta, Y Qian Journal of biomechanics 80, 88-94, 2018 | 33 | 2018 |
Hemodynamic effects of the anastomoses in the modified Blalock–Taussig shunt: a numerical study using a 0D/3D coupling method X Zhao, Y Liu, J Ding, X Ren, F Bai, M Zhang, L Ma, W Wang, J Xie, ... Journal of Mechanics in Medicine and Biology 15 (01), 1550017, 2015 | 26 | 2015 |
Towards the patient-specific design of flow diverters made from helix-like wires: an optimization study M Zhang, H Anzai, B Chopard, M Ohta Biomedical engineering online 15, 371-382, 2016 | 23 | 2016 |
Implementation of computer simulation to assess flow diversion treatment outcomes: systematic review and meta-analysis M Zhang, S Tupin, H Anzai, Y Kohata, M Shojima, K Suzuki, Y Okamoto, ... Journal of NeuroInterventional Surgery 13 (2), 164-170, 2021 | 12 | 2021 |
CTA-based non-invasive estimation of pressure gradients across a CoA: a validation against cardiac catheterisation M Zhang, J Liu, H Zhang, DI Verrelli, Q Wang, L Hu, Y Li, M Ohta, J Liu, ... Journal of Cardiovascular Translational Research, 1-10, 2021 | 6 | 2021 |
Associations between local haemodynamics and carotid intraplaque haemorrhage with different stenosis severities: A preliminary study based on MRI and CFD Y Dai, Y Qian, M Zhang, Y Li, P Lv, X Tang, A Javadzadegan, J Lin Journal of Clinical Neuroscience 66, 220-225, 2019 | 6 | 2019 |
Sensitivity study on modelling a flow-diverting stent as a porous medium using computational fluid dynamics Y Li, M Zhang, DI Verrelli, W Yang, W Chong, M Ohta, Y Qian 2017 39th Annual International Conference of the IEEE Engineering in …, 2017 | 6 | 2017 |
Hemodynamic influence of different pulmonary stenosis degree in Glenn procedure: a numerical study L Ma, Y Liu, X Zhao, X Ren, F Bai, J Ding, M Zhang, W Wang, J Xie, ... Advances in Mechanical Engineering 6, 472370, 2014 | 6 | 2014 |
A deep learning–based automatic system for intracranial aneurysms diagnosis on three‐dimensional digital subtraction angiographic images C Ou, Y Qian, W Chong, X Hou, M Zhang, X Zhang, W Si, CZ Duan Medical Physics 49 (11), 7038-7053, 2022 | 5 | 2022 |
Reliability of using generic flow conditions to quantify aneurysmal haemodynamics: a comparison against simulations incorporating boundary conditions measured in vivo B Li, T Liu, J Liu, Y Liu, B Cao, X Zhao, W Wang, M Shi, L Zhang, K Xu, ... Computer Methods and Programs in Biomedicine 225, 107034, 2022 | 5 | 2022 |
Non-invasive quantification of fraction flow reserve based on steady-state geometric multiscale models J Liu, X Wang, B Li, S Huang, H Sun, L Zhang, Y Sun, Z Liu, J Liu, L Wang, ... Frontiers in Physiology 13, 881826, 2022 | 5 | 2022 |
Evaluation of aneurysm rupture risk based upon flowrate-independent hemodynamic parameters: a multi-center pilot study M Zhang, X Hou, Y Qian, W Chong, X Zhang, CZ Duan, C Ou Journal of NeuroInterventional Surgery 15 (7), 695-700, 2023 | 4 | 2023 |
A parametric study of flushing conditions for improvement of angioscopy visibility K Mitsuzuka, Y Li, T Nakayama, H Anzai, D Goanno, S Tupin, M Zhang, ... Journal of Functional Biomaterials 13 (2), 69, 2022 | 4 | 2022 |
Incomplete stent expansion in flow‐diversion treatment affects aneurysmal haemodynamics: a quantitative comparison of treatments affected by different severities of … M Zhang, Y Li, S Sugiyama, DI Verrelli, Y Matsumoto, T Tominaga, Y Qian, ... International Journal for Numerical Methods in Biomedical Engineering 37 (7 …, 2021 | 4 | 2021 |
Association between aneurysmal haemodynamics and device microstructural characteristics after flow-diversion treatments with dual stents of different sizes: a numerical study M Zhang, S Tupin, Y Li, M Ohta Frontiers in Physiology 12, 663668, 2021 | 4 | 2021 |
Applying computer simulation to the design of flow-diversion treatment for intracranial aneurysms M Zhang, Y Li, DI Verrelli, W Chong, M Ohta, Y Qian 2017 39th Annual International Conference of the IEEE Engineering in …, 2017 | 4 | 2017 |
Haemodynamics in a patient-specific intracranial aneurysm according to experimental and numerical approaches: A comparison of PIV, CFD and PC-MRI Y Li, Y Yoneyama, H Isoda, M Terada, T Kosugi, T Kosugi, M Zhang, ... Technology and Health Care 29 (2), 253-267, 2021 | 3 | 2021 |
Manufacture-Oriented Design Optimisation of a Flow Diverter Stent Using Lattice Boltzmann Method and Simulated Annealing M Zhang, H Anzai, B Chopard, M Ohta 11th World Congress on Structural and Multidisciplinary Optimization, 2015 | 3 | 2015 |