Follow
Eva S Peper
Eva S Peper
Postdoc, University of Bern
No verified email - Homepage
Title
Cited by
Cited by
Year
Advancing cardiovascular, neurovascular, and renal magnetic resonance imaging in small rodents using cryogenic radiofrequency coil technology
T Niendorf, A Pohlmann, HM Reimann, H Waiczies, E Peper, ...
Frontiers in pharmacology 6, 255, 2015
492015
Highly accelerated 4D flow cardiovascular magnetic resonance using a pseudo-spiral Cartesian acquisition and compressed sensing reconstruction for carotid flow and wall shear …
ES Peper, LM Gottwald, Q Zhang, BF Coolen, P van Ooij, AJ Nederveen, ...
Journal of Cardiovascular Magnetic Resonance 22, 1-15, 2020
382020
Insufficient slow-flow suppression mimicking aneurysm wall enhancement in magnetic resonance vessel wall imaging: a phantom study
BMW Cornelissen, EL Leemans, BF Coolen, ES Peper, R van den Berg, ...
Neurosurgical focus 47 (1), E19, 2019
382019
High spatiotemporal resolution 4D flow MRI of intracranial aneurysms at 7T in 10 minutes
LM Gottwald, J Töger, KM Bloch, ES Peper, BF Coolen, GJ Strijkers, ...
American Journal of Neuroradiology 41 (7), 1201-1208, 2020
312020
Accelerated 4 D phase contrast MRI in skeletal muscle contraction
V Mazzoli, LM Gottwald, ES Peper, M Froeling, BF Coolen, N Verdonschot, ...
Magnetic resonance in medicine 80 (5), 1799-1811, 2018
292018
Regional assessment of carotid artery pulse wave velocity using compressed sensing accelerated high temporal resolution 2D CINE phase contrast cardiovascular magnetic resonance
ES Peper, GJ Strijkers, K Gazzola, WV Potters, AG Motaal, IK Luirink, ...
Journal of Cardiovascular Magnetic Resonance 20, 1-12, 2018
232018
Pseudo‐spiral sampling and compressed sensing reconstruction provides flexibility of temporal resolution in accelerated aortic 4D flow MRI: A comparison with k‐t principal …
LM Gottwald, ES Peper, Q Zhang, BF Coolen, GJ Strijkers, AJ Nederveen, ...
NMR in Biomedicine 33 (4), e4255, 2020
172020
Evaluation of compressed sensing MRI for accelerated bowel motility imaging
CS De Jonge, BF Coolen, ES Peper, AG Motaal, CY Nio, I Somers, ...
European Radiology Experimental 3, 1-12, 2019
142019
Advances in machine learning applications for cardiovascular 4D flow MRI
ES Peper, P van Ooij, B Jung, A Huber, C Gräni, JAM Bastiaansen
Frontiers in cardiovascular medicine 9, 1052068, 2022
102022
An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study
ES Peper, AM Leopaldi, S van Tuijl, BF Coolen, GJ Strijkers, J Baan, ...
European Radiology Experimental 3, 1-10, 2019
92019
30 times accelerated 4D flow MRI in the carotids using a pseudo spiral Cartesian acquisition and a total variation constrained compressed sensing reconstruction
E Peper, L Gottwald, Q Zhang, B Coolen, P van Ooij, G Strijkers, ...
Proc Intl Soc Mag Reson Med 26, 0012, 2018
92018
Pseudo spiral compressed sensing for aortic 4D Flow MRI: a comparison with kt principal component analysis
L Gottwald, E Peper, Q Zhang, B Coolen, G Strijkers, R Planken, ...
Proc Intl Soc Mag Reson Med 26, 3448, 2018
72018
Synthesis of patient-specific multipoint 4D flow MRI data of turbulent aortic flow downstream of stenotic valves
P Dirix, S Buoso, ES Peper, S Kozerke
Scientific reports 12 (1), 16004, 2022
62022
Whole‐Heart 4D Flow MRI for Evaluation of Normal and Regurgitant Valvular Flow: A Quantitative Comparison Between Pseudo‐Spiral Sampling and EPI Readout
CPS Blanken, LM Gottwald, JJM Westenberg, ES Peper, BF Coolen, ...
Journal of Magnetic Resonance Imaging 55 (4), 1120-1130, 2022
62022
Coronary flow assessment using accelerated 4D flow MRI with respiratory motion correction
CPS Blanken, EM Schrauben, ES Peper, LM Gottwald, BF Coolen, ...
Frontiers in bioengineering and biotechnology 9, 725833, 2021
52021
Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications
Y Safarkhanlo, B Jung, B Bernhard, ES Peper, RY Kwong, ...
The international journal of cardiovascular imaging 39 (10), 1963-1977, 2023
32023
Septaly oriented mild aortic regurgitant jets negatively influence left ventricular blood flow—insights from 4D flow MRI animal study
N Cesarovic, M Weisskopf, M Kron, L Glaus, ES Peper, S Buoso, ...
Frontiers in cardiovascular medicine 8, 711099, 2021
32021
Compressed Sensing accelerated 4D flow MRI using a pseudo spiral Cartesian sampling technique with random undersampling in time
LM Gottwald, ES Peper, Q Zhang, VQ Pronk, BF Coolen, P van Ooij, ...
Proc. Intl. Soc. Mag. Reson. Med 25, 2017
32017
Magnetic Resonance Imaging-Based 4D Flow: The Role of Artificial Intelligence
ES Peper, S Kozerke, P van Ooij
Artificial Intelligence in Cardiothoracic Imaging, 333-348, 2022
22022
Cine flow measurements using phase-contrast bSSFP at 0.75 Tesla
E Peper, H Dillinger, C McGrath, C Guenthner, S Kozerke
Proc. Int. Soc. Mag. Reson. Med 30, 0092, 2022
22022
The system can't perform the operation now. Try again later.
Articles 1–20