Follow
Jorge Bondia
Title
Cited by
Cited by
Year
Estimating plasma glucose from interstitial glucose: the issue of calibration algorithms in commercial continuous glucose monitoring devices
P Rossetti, J Bondia, J Vehí, CG Fanelli
Sensors 10 (12), 10936-10952, 2010
1412010
Comprehensive pharmacokinetic model of insulin glargine and other insulin formulations
C Tarin, E Teufel, J Picó, J Bondia, HJ Pfleiderer
IEEE Transactions on Biomedical Engineering 52 (12), 1994-2005, 2005
1002005
Enhancing automatic closed-loop glucose control in type 1 diabetes with an adaptive meal bolus calculator–in silico evaluation under intra-day variability
P Herrero, J Bondia, O Adewuyi, P Pesl, M El-Sharkawy, M Reddy, ...
Computer methods and programs in biomedicine 146, 125-131, 2017
812017
Safety auxiliary feedback element for the artificial pancreas in type 1 diabetes
A Revert, F Garelli, J Picó, H De Battista, P Rossetti, J Vehí, J Bondia
IEEE transactions on Biomedical Engineering 60 (8), 2113-2122, 2013
802013
Unannounced meals in the artificial pancreas: detection using continuous glucose monitoring
CM Ramkissoon, P Herrero, J Bondia, J Vehi
Sensors 18 (3), 884, 2018
742018
Real-time glucose estimation algorithm for continuous glucose monitoring using autoregressive models
Y Leal, W Garcia-Gabin, J Bondia, E Esteve, W Ricart, ...
Journal of diabetes science and technology 4 (2), 391-403, 2010
652010
Insulin estimation and prediction: A review of the estimation and prediction of subcutaneous insulin pharmacokinetics in closed-loop glucose control
J Bondia, S Romero-Vivo, B Ricarte, JL Diez
IEEE Control Systems Magazine 38 (1), 47-66, 2018
622018
Accuracy of continuous glucose monitoring before, during, and after aerobic and anaerobic exercise in patients with type 1 diabetes mellitus
L Biagi, A Bertachi, C Quirós, M Giménez, I Conget, J Bondia, J Vehí
Biosensors 8 (1), 22, 2018
592018
Real-time continuous glucose monitoring in an intensive care unit: better accuracy in patients with septic shock
C Lorencio, Y Leal, A Bonet, J Bondia, CC Palerm, A Tache, JM Sirvent, ...
Diabetes technology & therapeutics 14 (7), 568-575, 2012
582012
Automated blood glucose control in type 1 diabetes: A review of progress and challenges
A Bertachi, CM Ramkissoon, J Bondia, J Vehí
Endocrinología, Diabetes y Nutrición (English ed.) 65 (3), 172-181, 2018
552018
Method for automatic adjustment of an insulin bolus calculator: in silico robustness evaluation under intra-day variability
P Herrero, P Pesl, J Bondia, M Reddy, N Oliver, P Georgiou, C Toumazou
Computer methods and programs in biomedicine 119 (1), 1-8, 2015
542015
Closed-loop control of postprandial glycemia using an insulin-on-board limitation through continuous action on glucose target
P Rossetti, C Quiros, V Moscardo, A Comas, M Giménez, ...
Diabetes technology & therapeutics 19 (6), 355-362, 2017
512017
Analysis of linear systems with fuzzy parametric uncertainty
J Bondia, J Picó
Fuzzy sets and systems 135 (1), 81-121, 2003
512003
A new blood glucose control scheme for unannounced exercise in type 1 diabetic subjects
A Beneyto, A Bertachi, J Bondia, J Vehi
IEEE Transactions on Control Systems Technology 28 (2), 593-600, 2018
482018
El páncreas artificial: control automático de infusión de insulina en diabetes mellitus tipo 1
J Bondia, J Vehí, CC Palerm, P Herrero
Revista Iberoamericana de Automática e Informática Industrial RIAI 7 (2), 5-20, 2010
412010
Coordinated basal—bolus infusion for tighter postprandial glucose control in insulin pump therapy
J Bondia, E Dassau, H Zisser, R Calm, J Vehí, L Jovanovič, FJ Doyle III
Journal of diabetes science and technology 3 (1), 89-97, 2009
412009
Artificial pancreas system with unannounced meals based on a disturbance observer and feedforward compensation
R Sanz, P García, JL Díez, J Bondia
IEEE Transactions on Control Systems Technology 29 (1), 454-460, 2020
382020
Seasonal local models for glucose prediction in type 1 diabetes
E Montaser, JL Díez, P Rossetti, M Rashid, A Cinar, J Bondia
IEEE journal of biomedical and health informatics 24 (7), 2064-2072, 2019
382019
Real-time estimation of plasma insulin concentration from continuous glucose monitor measurements
D De Pereda, S Romero-Vivo, B Ricarte, P Rossetti, FJ Ampudia-Blasco, ...
Computer methods in biomechanics and biomedical engineering 19 (9), 934-942, 2016
362016
Robust sliding mode closed-loop glucose control with meal compensation in type 1 diabetes mellitus
W Garcia-Gabin, J Vehí, J Bondia, C Tarín, R Calm
IFAC Proceedings Volumes 41 (2), 4240-4245, 2008
362008
The system can't perform the operation now. Try again later.
Articles 1–20