Follow
Simon TUPIN
Simon TUPIN
Research Associate / Facility Manager, Department of Bioengineering, Imperial College London
Verified email at imperial.ac.uk - Homepage
Title
Cited by
Cited by
Year
What does computational fluid dynamics tell us about intracranial aneurysms? A meta-analysis and critical review
KM Saqr, S Rashad, S Tupin, K Niizuma, T Hassan, T Tominaga, M Ohta
Journal of Cerebral Blood Flow & Metabolism 40 (5), 1021-1039, 2020
912020
Physiologic blood flow is turbulent
KM Saqr, S Tupin, S Rashad, T Endo, K Niizuma, T Tominaga, M Ohta
Scientific Reports 10 (1), 1-12, 2020
712020
Prediction of 3D Cardiovascular hemodynamics before and after coronary artery bypass surgery via deep learning
G Li, H Wang, M Zhang, S Tupin, A Qiao, Y Liu, M Ohta, H Anzai
Communications Biology 4 (1), 1-12, 2021
692021
Evidence for non-Newtonian behavior of intracranial blood flow from Doppler ultrasonography measurements
KM Saqr, O Mansour, S Tupin, T Hassan, M Ohta
Medical & biological engineering & computing 57 (5), 1029-1036, 2019
282019
Effects of wall compliance on multiharmonic pulsatile flow in idealized cerebral aneurysm models: comparative PIV experiments
S Tupin, KM Saqr, M Ohta
Experiments in Fluids 61 (7), 1-11, 2020
262020
Epigenetic response of endothelial cells to different wall shear stress magnitudes: A report of new mechano‐miRNAs
S Rashad, X Han, K Saqr, S Tupin, M Ohta, K Niizuma, T Tominaga
Journal of cellular physiology 235 (11), 7827-7839, 2020
252020
Rheological behaviour of reconstructed skin
C Pailler-Mattei, L Laquièze, R Debret, S Tupin, G Aimond, P Sommer, ...
Journal of the mechanical behavior of biomedical materials 37, 251-263, 2014
242014
Mucoadhesion evaluation of polysaccharide gels for vaginal application by using rheological and indentation measurements
D Pliszczak, C Bordes, S Bourgeois, P Marote, H Zahouani, S Tupin, ...
Colloids and Surfaces B: Biointerfaces 92, 168-174, 2012
232012
Effects of Elasticity on Wall Shear Stress in Patient-Specific Aneurysm of Cerebral Artery
R Yamaguchi, T Kotani, G Tanaka, S Tupin, K Osman, NS Shafii, ...
Journal of Flow Control, Measurement & Visualization 7 (2), 73-86, 2019
142019
Development of a stereo dip-coating system for fabrication of tube-shaped blood vessel models
Y Shimizu, S Tupin, C Kiyomitsu, K Kitamura, K Takashima, M Ohta
Scientific Reports 10 (1), 1-10, 2020
132020
Multiscale Approach to Characterize Mechanical Properties of Tissue Engineered Skin
S Tupin, J Molimard, V Cenizo, T Hoc, B Sohm, H Zahouani
Annals of Biomedical Engineering 44 (9), 2851–2862, 2016
132016
Ex vivo approach to studying bio-adhesive and tribological properties of artificial salivas for oral dryness (xerostomia)
C Pailler-Mattei, R Vargiolu, S Tupin, H Zahouani
Wear 332, 710-714, 2015
122015
Implementation of computer simulation to assess flow diversion treatment outcomes: systematic review and meta-analysis
M Zhang, S Tupin, H Anzai, Y Kohata, M Shojima, K Suzuki, Y Okamoto, ...
Journal of NeuroInterventional Surgery 13 (2), 164-170, 2021
112021
Compliance Effect on the Flow Condition in Vascular In Vitro Experiments
M Matsuura, S Tupin, M Ohta
ASME International Mechanical Engineering Congress and Exposition 52026 …, 2018
72018
Assessing Porous Media Permeability in Non-Darcy Flow: A Re-Evaluation Based on the Forchheimer Equation
S Tupin, M Ohta
Materials 13 (11), 2535, 2020
62020
Development of Ultrasound Phantom Made of Transparent Material: Feasibility of Optical Particle Image Velocimetry
MSS Hashuro, S Tupin, NK Putra, K Daibo, K Inoue, T Ishii, ...
Ultrasound in Medicine & Biology 49 (6), 1385-1394, 2023
52023
Non-Kolmogorov Turbulence and Inverse Energy Cascade in Intracranial Aneurysm: Near-Wall Scales Suggest Mechanobiological Relevance
S Tupin, KM Saqr, S Rashad, K Niizuma, M Ohta, T Tominaga
arXiv preprint arXiv:2001.08234, 2020
52020
Multipoint pressure measurement in blood vessel model for evaluation of intravascular treatment of cerebral aneurysm using fiber-optic pressure sensors
T Matsunaga, Y Haga, S Osaki, Y Shimizu, S Tupin, M Ohta, M Shojima, ...
2017 IEEE International Conference on Cyborg and Bionic Systems (CBS), 136-139, 2017
52017
A Parametric Study of Flushing Conditions for Improvement of Angioscopy Visibility
K Mitsuzuka, Y Li, T Nakayama, H Anzai, D Goanno, S Tupin, M Zhang, ...
Journal of Functional Biomaterials 13 (2), 69, 2022
42022
Experimental Analysis of Pressure and Flow Alterations During and After Insertion of a Multilayer Flow Modulator into an AAA Model with Incorporated Branch
S Tupin, K Takase, M Ohta
CardioVascular and Interventional Radiology 44 (8), 1251-1259, 2021
42021
The system can't perform the operation now. Try again later.
Articles 1–20