Optimal combination of anti‐scatter grids and software correction for CBCT imaging U Stankovic, LS Ploeger, M van Herk, JJ Sonke Medical physics 44 (9), 4437-4451, 2017 | 56 | 2017 |
Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber‐interspaced antiscatter grid U Stankovic, M van Herk, LS Ploeger, JJ Sonke Medical physics 41 (6Part1), 061910, 2014 | 45 | 2014 |
Evaluating the impact of cone-beam computed tomography scatter mitigation strategies on radiotherapy dose calculation accuracy L Schröder, U Stankovic, P Remeijer, JJ Sonke Physics and Imaging in Radiation Oncology 10, 35-40, 2019 | 23 | 2019 |
The first implementation of respiratory triggered 4DCBCT on a linear accelerator R T O’Brien, BJ Cooper, CC Shieh, U Stankovic, PJ Keall, JJ Sonke Physics in Medicine & Biology 61 (9), 3488, 2016 | 21 | 2016 |
Reducing 4DCBCT imaging time and dose: the first implementation of variable gantry speed 4DCBCT on a linear accelerator R T O’Brien, U Stankovic, JJ Sonke, PJ Keall Physics in Medicine & Biology 62 (11), 4300, 2017 | 15 | 2017 |
Long‐term stability of Hounsfield unit calibration for cone beam computed tomography L Schröder, U Stankovic, JJ Sonke Medical physics 47 (4), 1640-1644, 2020 | 11 | 2020 |
Clinical introduction of image lag correction for a cone beam CT system U Stankovic, LS Ploeger, JJ Sonke, M Van Herk Medical physics 43 (3), 1057-1064, 2016 | 11 | 2016 |
Mitigating differential baseline shifts in locally advanced lung cancer patients using an average anatomy model M Abdoli, SR Van Kranen, U Stankovic, MMG Rossi, JSA Belderbos, ... Medical Physics 44 (7), 3570-3578, 2017 | 6 | 2017 |
WE‐AB‐207A‐11: Respiratory Motion Guided 4DCBCT‐A Step Towards Controlling 4DCBCT Image Quality R O'Brien, U Stankovic, P Keall, J Sonke Medical physics 43 (6Part39), 3800-3800, 2016 | 4 | 2016 |
Image quality of dual-energy cone-beam CT with total nuclear variation regularization L Schröder, U Stankovic, S Rit, JJ Sonke Biomedical Physics & Engineering Express 8 (2), 025012, 2022 | 2 | 2022 |
Improving linac integrated cone beam computed tomography image quality using tube current modulation U Stankovic, LS Ploeger, JJ Sonke Medical Physics 48 (4), 1739-1749, 2021 | 1 | 2021 |
PO-0892: Introduction of image lag correction on clinical cone-beam CT systems LS Ploeger, U Stankovic, C Panneman, M Van Herk, JJ Sonke Radiotherapy and Oncology, S101-S102, 2014 | 1 | 2014 |
Impact of cone‐beam computed tomography artifacts on dose calculation accuracy for lung cancer L Schröder, G Bootsma, U Stankovic, L Ploeger, JJ Sonke Medical Physics, 2024 | | 2024 |
Clinical feasibility of CBCT-based online plan adaptation for multiple lesion brain SRS G Wortel, U Stankovic, J Trinks, G Sotiropoulos, S Van Kranen, ... Radiotherapy and Oncology 133, S1084-S1084, 2019 | | 2019 |
Reducing 4DCBCT imaging time and dose: The first implementation of variable gantry speed 4DCBCT on a linear accelerator P Keall, R O'Brien, J Sonke, U Stankovic Institute of Physics Publishing, 2017 | | 2017 |
EP-1741: Impact of anti-scatter grid design image quality of CBCT scans for head and neck cancer imaging U Stankovic, M Van Herk, LS Ploeger, S Van Kranen, JJ Sonke Radiotherapy and Oncology, S265, 2014 | | 2014 |
PO-0872: Evaluation of a novel anti-scatter grid for CBCT guided radiotherapy U Stankovic, LS Ploeger, M van Herk, JJ Sonke Radiotherapy and Oncology 106, S338, 2013 | | 2013 |
Vernier and meter-testing potentiometers A Mohan, S Mohanasankar, VJ Kumar, R T O’Brien, U Stankovic, ... | | |